What we build
Stair-type fire escapes
Landings at each floor connected by stairs, the zigzag you see on brick walk-ups.
Balconies with drop ladders
Platforms at the upper floors with a counterbalanced or sliding ladder to the ground.
Exterior spiral stairs
A compact egress stair where there isn't room for straight runs.
Rear egress stairs and landings
Steel stairs for two- and three-family houses and small commercial buildings.
Fixed and caged ladders
Roof and access ladders with safety cages.
Railings to match
New guards and handrails on existing stairs and porches. See exterior railings.
From survey to installed
- 01
Survey and measure
We measure the building, the openings and the ground below, and look at what the anchors will go into.
- 02
Design and drawings
Layout of landings, stairs and connections. Your building department may require stamped drawings; we work with the engineer when it does.
- 03
Permit
In Boston, a new fire escape goes under a Long-Form Permit with Inspectional Services. Other cities have their own process.
- 04
Fabrication in Everett
Platforms, stairs, rails and brackets are cut, welded and primed in our shop.
- 05
Removal and installation
Our crew removes the old fire escape if there is one and installs the new one, anchoring each level.
- 06
Finish and sign-off
Paint, a walk-through, and the inspection and paperwork the permit calls for.
New fire escapes and egress stairs we've installed








What shapes the cost and timeline
We don't publish prices. These are the things that decide them.
Design
- Number of floors and landings
- Stair type: zigzag, spiral or ladder
- Whether stamped engineering drawings are required
Site
- Access for a lift or crane
- What the anchors go into: brick, block or wood framing
- Removing and hauling away an old fire escape
Paperwork
- Permit review time in your city
- Historic district review, if your building is in one
- Final inspection and filing
Questions we get asked
When should a fire escape be replaced instead of repaired?
When the platforms, stairs and wall connections are failing together, or the layout no longer works for the building. If only some members are bad, repair is usually the better choice. See fire escape repair.
Do I need a permit for a new fire escape?
Yes. In Boston, a new fire escape needs a Long-Form Permit from Inspectional Services. Other cities issue building permits through their own departments.
Do I need an engineer?
Often, for a new fire escape. Many building departments want stamped drawings for new structural work. We work with the engineer and build to the approved drawings.
How long does a new fire escape take?
The permit and drawings usually take longer than the steel. Once those are approved, shop fabrication and installation are scheduled together so the crew arrives with everything ready.
Can you build a spiral fire escape?
Yes. Exterior spiral egress stairs are in our portfolio and on this page.
Related
New fire escapes for commercial buildings
Planning a new install on an apartment or commercial building.